Martindale Voltage Indicator & Proving Unit

Click Images to Enlarge

Martindale Order Code: MARVIPD
Print Page   Bookmark this page  
   Buy Now
Martindale VI137002 Voltage Indicator

Martindale VI137002 Voltage Indicator

Martindale TEK100 Non Contact Voltage Detector

Martindale TEK100 Non Contact Voltage Detector


Product Details

Nothing is more dangerous than trusting a defective voltage indicator to test for a dead circuit. Safe electrical work requires the use of a voltage indicator that has been proved with a proving unit before and after use.

The Martindale VIPD contains the VI137002 voltage indicator and the PD440 proving unit, enabling you to comply with health and safety recommendations for safe working.

Specification

Martindale VI13700/2 Voltage Indicator Specifications

Voltage Ranges

  • 50 - 400V AC/DC
  • LED Indication

  • +/-50, 100, 200, 400V
  • Polarity Indication

  • from 12V
  • AC / DC Voltage Detection

  • Automatic
  • Range Detection

  • Automatic
  • Response Time

  • <0.1s
  • Frequency Range

  • DC, 0 - 65Hz
  • Test Current

  • 3.5mA max at 400V AC/DC
  • Duty Ratio

  • 30s ON / 240s Off
  • Temperature Range

  • -10°C to +55°C
  • Humidity

  • max. 85% rel. H
  • Altitude

  • up to 2000m
  • Overvoltage Category

  • CAT IV / 600V, CATIII 1000V
  • Pollution Degree

  • 2
  • Environmental Protection

  • IP54
  • Safety

  • GS38, BS EN 61010
  • Weight

  • approx 130g
  • Dimensions

  • approx 205 x 67 x 27
  • Martindale PD440 Specification

    Output Voltage

  • 440V, 50Hz
  • Operating Temperature

  • -10°C to +40°C at max 70% RH
  • Battery

  • 6 x LR6 / MN1500 1.5V alkaline batteries or equivalent
  • Dimensions

  • 143 x 84 x 50mm
  • Weight

  • 400g approx including battery
  • PDF Manual

                                                              

    Martindale VI13700/2 Instruction Manual        Martindale PD440 Instruction Manual

    Ask a question

       Accessories & Spares For This Product
    Martindale VI137002 Voltage Indicator
    Martindale VI137002 Voltage Indicator
    Martindale PD690 - 690V Proving Unit
    Martindale PD690 - 690V Proving Unit
    Martindale TC69 VIPD Soft Carry Case
    Martindale TC69 VIPD Soft Carry Case



    Gambica Membership    Martindale Electric - Quality Assured    Martindale Electric - Quality Assured    Achilles Membership    Martindale Electric - Quality Assured Martindale Electric Ltd, Metrohm House, Penfold Trading Estate, Imperial Way,
    Watford, Hertfordshire, WD24 4YY
    © Copyright 1998-2012 Martindale Electric Company Ltd.
    All Rights Reserved. Registered in England No. 3387451.
    Privacy Notice  |  Terms & Conditions  |  Contact Us  |  Careers  |  Links  |  Sitemap